AudiologyOnline Phone: 800-753-2160


Exam Preview

Advanced Target Programming

View Course Details Please note: exam questions are subject to change.


1.  An easy way to walk through a fitting in Target Software without devices is through the use of which of the following features?
  1. Audiogram Direct
  2. Datalogging
  3. New Training Session
  4. Automatic Fine Tuning
2.  When making multiple adjustments for a patient, you can easily compare one setting to another by using which functions?
  1. Capture It
  2. Audiogram Direct
  3. Compare settings
  4. Automatic Fine Tuning
3.  When a patient reports that upon entering into a noisy environment and having to wait too long for their hearing aids to adjust, what are two of the ways you can address the concern?
  1. Change gain level to 70%
  2. Move “blending” slider to “fast” or “very fast”
  3. Move “activation level” slider for Speech in Loud Noise to the left (i.e. lower the activation level)
  4. B&C
4.  When a patient reports they have a very dynamic listening environment in which they would like to attenuate their microphones if necessary, what is the one way to give them that ability?
  1. Add a tcoil program
  2. Give them a ComPilot II
  3. Demonstrate Environmental Balance 
  4. Tell the patient to turn volume down
5.  The adjustment sliders for SR2 are labeled what? (4 labels total)
  1. Clarity/Comfort/Audibility/Distinction
  2. Weaker/Stronger/Intelligibility/Distinction
  3. Clarity/Comfort/On/Off
  4. Weaker/Stronger/On/off
6.  Which of the following are significant about SoundRecover2?
  1. It is adaptive
  2. It is flexible
  3. It results in less distortion
  4. All of the above
7.  When Audibility/Distinction slider is adjusted towards Distinction, frequency lowering essentially becomes what?
  1. Weaker
  2. Stronger
  3. Non-existent
  4. none of the above
8.  For access to fine tuning suggestions and to have Target Software make appropriate adjustments to your fitting, which software tool is appropriate?
  1. Audibility Fine Tuning
  2. Program Options
  3. Automatic Fine Tuning
  4. Device Options
9.  What parameters does an audiologist have control over for AutoSense OS programs?
  1. Gain
  2. Noise Reduction
  3. Feedback Management
  4. All of the above
10.  Where is TargetMatch located in Target fitting software?
  1. Global Tuning
  2. Fine Tuning
  3. Feedback & Real Ear test
  4. Acoustic parameters

Our site uses cookies to improve your experience. By using our site, you agree to our Privacy Policy.