AudiologyOnline Phone: 800-753-2160


Unitron Choice - November 2024

What is Considered a Standard Threshold Shift?

Richard Danielson, PhD

January 1, 2007

Share:

Question

Do we have documentation of what is considered a significant shift in hearing? They're using 15dB or more in at least two different frequencies, but not sure if that is a good guideline or not.

Answer

Noise-exposed workers receive an annual hearing test for comparison to baseline hearing threshold levels that were obtained when the worker was first assigned to a noise-hazardous job. When these periodic tests reveal a meaningful change from baseline data, this change should trigger certain steps (e.g., checking the fit of hearing protectors, reinstructing the worker on risks of hearing loss from noise, etc.) to prevent further progression of hearing loss. Ideally, monitoring audiometry programs can identify those noise-exposed workers with measurable hearing threshold shift at the most noise-sensitive audiometric frequencies and not tag too many false positives. Your question, "what is considered a significant shift in hearing?", can be answered in terms of compliance with federal hearing conservation standards or in terms of "best practices" that encourage a "pro-active" approach to preventing noise-related hearing loss.

The current federal hearing conservation standards of the Occupational Health and Safety Administration (OSHA) have not changed since 1983. Using OSHA criteria, a reviewer of audiograms will identify an STS (or "Standard Threshold Shift") if the hearing threshold has changed (relative to the baseline audiogram) an average of 10dB or more at 2000, 3000, or 4000 Hz in either ear. Age corrections (listed as an appendix in the OSHA standard) may be used when determining STS, although they are not required. Another federal agency, the Mine Safety and Health Administration (MSHA), has also adopted the OSHA STS criteria.

More recently, the National Institute of Occupational Safety and Health (NIOSH) has proposed new criteria to identify noise-induced hearing loss (NIHL) earlier, thereby going beyond attempts to conserve hearing by instead focusing on preventing NIHL. (Similarly, safety and health personnel are gradually changing the names of their programs from hearing conservation programs to hearing loss prevention programs.) NIOSH has recommended that OSHA and MSHA revise their STS criteria to a definition of an increase of 15 dB or more at any frequency (500, 1000, 2000, 3000, 4000, or 6000 Hz) in either ear that is confirmed for the same ear and frequency by a second test within 30 days of the first test. Because the STS must be confirmed in a second hearing test, these criteria are referred to as the "15dB TWICE" method. Interestingly, the criteria which you mentioned (15dB or more in at least two different frequencies) seems similar to the 15dB TWICE method, but is clearly NOT the same as the NIOSH criteria. Moreover, if a 15dB shift occurred in two of the frequencies of interest in the OSHA criteria (i.e., 2000, 3000, or 4000 Hz), it would be mathematically impossible to have anything EXCEPT an STS. Even if the third frequency "improved" by -10dB, it would yield an average shift of 10dB. By the way, NIOSH does not support the use of age corrections.

The "15dB in two frequencies" criteria that you mention are not a common method of determining STS. In 1992 and 1996, Julia Royster conducted studies for NIOSH, in which she compared the performance of eight known criterion (none of which was 15dB in two frequencies):

  1. OSHA STS: in either ear, a change of 10 dB or more in the average of hearing thresholds at 2000, 3000, and 4000 Hz.

  2. OSHA STS TWICE: in either ear, a change of 10 dB or more in the average of hearing thresholds at 2000, 3000, and 4000 Hz is present on one annual audiogram and is persistent in the same ear on the next audiogram.

  3. American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) SHIFT: in either ear, a change of 10 dB or more in the average of hearing thresholds at 500, 1000, and 2000 Hz, or 15 dB or more at 3000, 4000, and 6000 Hz.

  4. NIOSH SHIFT (1972 version): in either ear, a change of 10 dB or more at 500, 1000, 2000, or 3000 Hz, or 15 dB or more at 4000 or 6000 Hz.

  5. 15-dB SHIFT: in either ear, a change of 15 dB or more at any test frequency from 500 through 6000 Hz.

  6. 15-dB TWICE (current NIOSH version): in either ear, a change of 15 dB or more at any test frequency from 500 through 6000 Hz is present on one annual audiogram and is persistent at the same frequency in the same ear on the next audiogram.

  7. 15-dB TWICE 1B4 kHz: in either ear, a change of 15 dB or more at any test frequency from 1000 through 4000 Hz is present on one annual audiogram and is persistent at the same frequency in the same ear on the next audiogram.

  8. 10-dB AVG 3B4 kHz: in either ear, a change of 10 dB or more in the average of hearing thresholds at 3000 and 4000 Hz.
None of the criterion evaluated were best in every respect (e.g., tagging workers early, giving high percentage of true positives, tagging a moderate percentile of workers so follow-up is practical, not considering low frequencies that are unlikely affected by noise exposure, etc.). However, NIOSH selected the 15dB TWICE approach because it identifies a high number of workers and provides a warning of noise-induced shifts at 6000 Hz, a noise-susceptible test frequency. While most occupational health programs use the OSHA STS criteria, NIOSH's STS criteria is being closely examined for possible application in industrial and military programs.

No matter what technique is used, our overall objective should be to prevent unnecessary hearing loss. As the American Academy of Audiology stated in its 2002 Position Statement, "No one needs to lose his or her hearing in order to earn a living. Noise-induced hearing loss is preventable." Good luck in your efforts.

Addendum:


A reader has asked for a clarification between the OSHA's basic definition of STS, described in OSHA's Hearing Conservation Amendment [29 CFR 1910.95 (1983)] and OSHA's guidelines for a recordable STS [29 CFR 1904.10 (2002)].

I'm happy to elaborate on how a basic STS is different from a recordable STS. OSHA's basic definition of STS (as I described in my initial response) is unchanged since 1983's description, although the requirements for reporting an STS to OSHA were updated, effective January 2003. As shown below, if an individual had an STS, but did not have a hearing loss (defined, in this case, as a pure tone average at 2,3,4 kHz of 25 dB or more), OSHA would not require you to report this shift. This figure may help clarify the OSHA reporting rule:





Reconfirmation of STS: If the annual audiogram shows a STS, a hearing retest may be performed within 30 days. If the retest does not confirm the STS, then the case need not be recorded. However, if the retest confirms the STS and the hearing loss is work-related, it must be recorded within 7 calendar days of retest. If a retest is not performed, then the case (again, if work-related) must be recorded within 37 days of test.

Results of subsequent testing: If later testing is performed as part of the hearing conservation program, and indicates that the STS is not persistent, then the employer may erase or line-out the recorded entry.

Determination of work-relatedness: Work-relatedness must be determined according to specifications of 29 CFR 1904.5 of OSHA's Recording and Reporting Occupational Injuries and Illness standard. If an event/exposure in the workplace caused, or contributed to, the shift in hearing or "significantly aggravated" a previously existing hearing loss, then the STS is recordable.

See links at https://www.caohc.org/current_events/oshafinal.php for more information


Dr. Richard Danielson is the Manager for Audiology and Hearing Conservation for NASA-Johnson Space Center, Houston, TX. He works for the National Space Biomedical Research Institute and Baylor College of Medicine. He is a retired U.S. Army audiologist, who served as a consultant to the Army Hearing Conservation program and director of the Army Audiology and Speech Center, Walter Reed Army Medical Center. He can be contacted at richard.danielson@jsc.nasa.gov.


Richard Danielson, PhD


Related Courses

20Q: Audiologic Care for Musicians - Creating the Perfect Harmony
Presented by Cory Portnuff, AuD, PhD
Text/Transcript
AudiologyOnline

Presenter

Cory Portnuff, AuD, PhD
Course: #36100Level: Intermediate1 Hour
  'Interesting information about verification'   Read Reviews
Musicians' ears are part of their instruments, and audiology expertise is important for amateur as well as professional musicians. Standard audiology clinic protocols and knowledge may not always be on target for musicians. This course uses an engaging Q & A format to discuss musicians' unique hearing needs and how audiologists can best meet them.

View this Course for FREE.
Need CEUs? Become a AudiologyOnline member to get unlimited CEUs.

Only $129/yr

Learn More

Innovative Audiologic Care Delivery
Presented by Rachel Magann Faivre, AuD, Lori Zitelli, AuD, Heather Malyuk, AuD, Ben Thompson, AuD
Recorded Webinar
AudiologyOnline

Presenters

Rachel Magann Faivre, AuDLori Zitelli, AuDHeather Malyuk, AuDBen Thompson, AuD
Course: #38661Level: Intermediate4 Hours
  'informative'   Read Reviews
This four-course series highlights the next generation of audiology innovators and their pioneering approaches to meeting unmet audiologic needs in their communities and beyond. This peer-to-peer educational series highlights researchers, clinicians, and business owners and their pioneering ideas, care delivery models, and technologies which provide desperately needed niche services and audiologic care.

View this Course for FREE.
Need CEUs? Become a AudiologyOnline member to get unlimited CEUs.

Only $129/yr

Learn More

Assessment of Firearm Noise Exposures and Hearing Loss Prevention
Presented by William Murphy, PhD
Recorded Webinar
AudiologyOnline

Presenter

William Murphy, PhD
Course: #31240Level: Advanced1 Hour
  'material presented'   Read Reviews
This seminar will describe the magnitude of firearm noise exposure and will describe noise reduction solutions and hearing protection recommendations.

View this Course for FREE.
Need CEUs? Become a AudiologyOnline member to get unlimited CEUs.

Only $129/yr

Learn More

Best Practices for Music Industry Patients: Recommendations and "Real World" Care
Presented by Heather Malyuk, AuD
Recorded Webinar
AudiologyOnline

Presenter

Heather Malyuk, AuD
Course: #33289Level: Advanced1 Hour
  'Very clear presentation'   Read Reviews
This course discusses best practices care for the music industry. From recommended diagnostic procedures to seeing a band backstage at a venue, attendees will learn how to modify best practices to suit clinical and “real world” situations.

View this Course for FREE.
Need CEUs? Become a AudiologyOnline member to get unlimited CEUs.

Only $129/yr

Learn More

Telehealth and Modern Hearing Conservation
Presented by Heather Malyuk, AuD
Recorded Webinar
AudiologyOnline

Presenter

Heather Malyuk, AuD
Course: #38412Level: Introductory1 Hour
  'discussing how to use tele-audiology in modern audiology practice'   Read Reviews
An introduction and examination of the role of teleaudiology in modern audiologic practice are discussed in this course. In particular, as it relates to non-regulated hearing conservation in the modern workforce. This course is part of a four-course series, Destroying the Box: Innovative Audiologic Care Delivery which highlights the next generation of audiology innovators and their pioneering approaches to meeting unmet audiologic needs in their communities and beyond.

View this Course for FREE.
Need CEUs? Become a AudiologyOnline member to get unlimited CEUs.

Only $129/yr

Learn More

Our site uses cookies to improve your experience. By using our site, you agree to our Privacy Policy.